DESCRIPTION

DECK-O-SHIELD is a ready-to-use, water-based sealer/water repellant for natural
stone, concrete, and masonry surfaces. DECK-O-SHIELD is designed for use as
a sealer/water repellent on waterfalls in or around swimming pools; the product
will limit the penetration of water into structurally sound, crack-free surfaces.
The product also can be used as a sealer/water repellant for natural stone decks,
walkways, or patios; virtually any area located near or around swimming pool
areas. A DECK-O-SHIELD-treated surface will inhibit the penetration of salts
into the surface, reducing “whitening” or staining.
| USES DECK-O-SHIELD weatherproofs and protects virtually all waterfalls, decks, porches, patios, and walkways around pools, including the following surfaces: |
|
| Another advantage DECK-O-SHIELD provides is that the product will not alter the color or tint of the surface after application. There is no need for worry when applying DECK-O-SHIELD, because the product will have no adverse effects on surface appearance after application. |
| FEATURES/BENEFITS |
|
PACKAGING
1 Gallon (3.79 Liter) Units
5 Gallon (18.93 Liter) Pails
| PROPERTIES | |
| Dry to Touch Flash Point Color |
1 - 2 hours (Typical) Allow 12 -14 hours between coats for multiple coat applications > 210° F Milky White Emulsion |
|
Natural Stone** Concrete Masonry Stucco Surfaces Concrete Block** |
75 -175 ft.²/gal 100 -175 ft.²/gal 100 -175 ft.²/gal 60 -100 ft.²/gal 50 -100 ft.²/gal** |
PREPARATION
Protect people, vehicles, property, plants, and all non-masonry surfaces from
product, splash, residue, and wind drift. Thoroughly clean the surface. Though
DECK-O-SHIELD may be applied to slightly damp surfaces, best performance is
achieved on a clean, thoroughly dried and absorbent surface. Excessive moisture
inhibits penetration, reducing the service life and performance of the treatment.
Always test for compatibility. Surfaces must be structurally sound, clean and
free from dirt, efflorescence, and stains.
SURFACE AND AIR TEMPERATURES
Optimum surface and air temperature is 40°-95° F (4°-35° C)
during application and eight hours after. If freezing conditions exist before
application, let surface to receive treatment thaw. The DECK-O-SHIELD water
carrier may freeze at low temperatures or evaporate at high temperatures. Both
conditions impair penetration and results.
EQUIPMENT
Apply with brush, roller or low-pressure spray (<50 psi), depending on surface
texture, area, etc. Fan tips are recommended for sprayers.
TEST APPLICATION
Always perform a test application on each type of surface prior to full-scale
application to determine suitability and final appearance. Test using the recommended
application instructions. Let area dry thoroughly before inspection.
VERTICAL APPLICATION INSTRUCTIONS
For best results, apply to a visibly dry and absorbent surface.
Spray …Saturate from the bottom up, creating a 4" - 8" (10 - 20 cm) rundown below the spray contact point. Let the first application penetrate for 5 – 10 minutes. Re-saturate while surface still appears moist. Less product will be needed for the second application.
Brush or Roller …Saturate uniformly. Let penetrate for 5 - 10 minutes. Brush out heavy runs and drips that do not penetrate.
DENSE SURFACE APPLICATION
INSTRUCTIONS
Apply a single coat. Use enough to completely wet the surface without producing
drips, puddles or rundown. DO NOT OVERAPPLY.
HORIZONTAL APPLICATION INSTRUCTIONS
1. Saturate in a single application. Use enough to keep surface wet for 2 --
3 minutes before penetration.
2. Broom out puddles until they soak in.
Note: Hot, windy conditions will evaporate the water carrier, reducing penetration and performance. On hot, windy days, apply early in the day and in shade, if possible.
Treated surfaces dry to touch in 1 - 2 hours. Protect surfaces from rainfall for six hours following treatment. Many surfaces need several days to develop optimum water repellency.
ADDITIONAL COATS
Once the surface being treated has received the optimum amount of DECK-O-SHIELD,
any additional coats will bead up on the surface. Discontinue application once
this occurs. The CS-309™, EXPO-GLOSS®, DECRA-SEAL™ and VOCOMP®
series of products, as well as TIAH®, all from MEADOWS, can be applied over
a DECK-O-SHIELD-treated surface. The resulting barrier will provide water beading
and, depending on product used, will also provide a glossy surface appearance.
The initial application of DECK-O-SHIELD must be applied properly and at recommended
application rate.
Cleanup ... Immediately clean tools, equipment and overspray with soap and warm water.
PRECAUTIONS
DO NOT DILUTE OR ALTER. MIX CONTAINER THOROUGHLY PRIOR TO USE. DO NOT FREEZE.
DECK-O-SHIELD is a water repellent, not a waterproofing or vapor barrier. It will not hide existing surface stains. DECK-O-SHIELD should not be applied to surfaces that are to receive caulks or sealants. Application over fully cured elastomeric sealants typically will not affect the sealant. Do not apply to surfaces with temperatures of <40° F or >95° F. Prevent from being spilled or over sprayed onto nearby water sources. Temporary darkening of some substrates may occur. Apply a small test patch application prior to full-scale application. Refer to Material Safety Data Sheet for complete health and safety information.
November 2007
LIMITED
WARRANTY
"DECK-O-SEAL®, A Division of W. R. MEADOWS, INC., warrants
at the time and place we make shipment, our material will be of
good quality and will conform with our published specifications
in force on the date of acceptance of the order." Read complete
warranty. Copy furnished upon request.
Disclaimer
The information contained herein is included for illustrative
purposes only, and to the best of our knowledge, is accurate and
reliable. DECK-O-SEAL cannot however under any circumstances make
any guarantee of results or assume any obligation or liability
in connection with the use of this information. As DECK-O-SEAL
has no control over the use to which others may put its product,
it is recommended that the products be tested to determine if
suitable for specific application and/or our information is valid
in a particular circumstance. Responsibility remains with the
architect or engineer, contractor and owner for the design, application
and proper installation of each product. Specifier and user shall
determine the suitability of products for specific application
and assume all responsibilities in connection therewith.